pH - mV - Ion - Conductivity - Resistivity - TDS - Dissolved oxygen - Temperature
D230
- pH: 0...14 pH
- mV: ± 2000 mV
- Ion: 0...100g/l
- Conductivity: 0...2000 mS/cm
- TDS: 0...100g/l
- Dissolved oxygen: 0...60 mg/l,
- Temperature: -5...+105°C
Cena na dotaz
0 Kč
Vč. DPH
0 Kč bez DPH
Modular System
- Built in a standard 19 inch rack + cabinet the central unit accepts up to 7 modules. Different modules can be mixed in one unit.
- There are two modules available: D291 & D292
- D291: 4 pH/mV/Ion/dissolved oxygen + 4 temperature channels,
- D292: 4 conductivity/TDS + 4 temperature channels.
- Up to 16 units can be combined with each other to increase the number of channels up to 448.
- All parameters including set-up, calibration and display are controlled through any computer via a single RS232 connection.
- Up to 16 units can be combined with each other to increase the number of channels to a maximum
pH
- One- or two point calibration.
- Selectable resolution from 0.001 pH to 0.1 pH
- Automatic calibration with any of 9 pre-programmed and 2 user specified pH buffers
mV
- Features mV calibration
- Selectable resolution for accurate ORP measurements.
Ion
- Direct concentration measurement.
- Shows concentration in any unit.
- Ion mode is easily calibrated with any two standards and a blank correction.
Dissolved oxygen
- Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%)
- Rapid air calibrationn, no zero calibration required.
- Manuel salinity compensation 0-40
- Manuel air pressure compensation 800-1200 hPa.
Temperature
- Manuel or automatic temperature compensation .
- Calibrates temperature probe for quality measurements.
Conductivity
- One point calibration
- Use a 1 cm-1 electrode(standard) to measure from 0.01 µS/cm to 200 mS/cm.
- Use a 0.01 cm-1 electrode to measure from 0.001 µS/cm to 2 mS/cm.
- Use a 0.1 cm-1 electrode to measure from 0.01 µS/cm to 20 mS/cm.
- Use a 10 cm-1 electrode to measure from 1 µS/cm to 2000 mS/cm.
- Selectable refernce temperature: 20° or 25°C
- Automatic calibration with any of three preprogrammed and three user specified standard solutions.
- Accurate low conductivity measurements by eliminating the capacitve component of the electrode and its cable (avoid the use of long cables!).
Special features
- Three year warrenty
- No electrical interference between electrodes in th e same solution.
Data acquisition
- The software package supplied with the D230 is specially designed to control, collect and store data. Runs under WindowsTM 2000 or higher.
- All channels are processed at the same time, each in its own window.
- The sofware automatically detects the maximum number and type of available channels.
- Data is collected on-line at a programmable interval determined by the program (4s...24h).
Table
- Data is always stored in a table.
- Each module has its own programmable table containing an unlimited number of lines (maximum depends on available computer memory).
- Comments can easily be added to each line in a special information column.
Starting
- Data-logging can start/stop automatically or at a programmable date/time
- Data-logging can be stopped or continued at any moment.
Files
- All data is saved in a user defined file. Just open the file to view, process or print the stored data.All measurements are saved in CSV format which is easily transferred into spreadsheets.
- All data is saved in a user defined file. Just open the file to view, process or print the stored data.
Graphs
- Graphs are generated using automatic or user defined settings.
- The number of visible values can be changed at any time.
- Programmable alarm limits for each graph allow to print a report indicating when limits have been exceeded.
- Shows statistics about minima, maxima, averages etc..
Settings
- Languages: English, Dutch, or French
- The style of each window can be set up separately.
- Choose fonts, colours etc...
- Documented printouts will show:-file name--name of operator-- name of the company-- name of the division-- optional notes by the operator.
- All settings are stored in a configuration file and automatically recalled when opening the program.
Functions
- All functions are accessible through the menu.
- Only valid options appear in the menu to eliminate set-up errors.
- Special buttons, icons and short-keys allow the user to easilly access the most useful functions.
- The contents of each window can be transferred to other program by using a copy function. Tile or cascade the windows and arrange the icons fully automatically or rearrange them manually.
CODE | DESCRIPTION |
D230 | Data-logger: central unit for 7 modules + software + RS232 cable + mains lead. |
D291 | Module for pH/mVIon/O2/°C with 4+4 channels |
D292 | Module for conductivity/TDS°C with 4+4 channels |
D298 | Data cable to connect 2 data-loggers with each other (optional) |
D299 | Blanc frontpanel to cover unused module space (optional) |