pH - mV - Conductivity - Salinity - TDS - Dissolved oxygen - Temperature
C5020
Specifications
- pH: 0...14 pH
- mV: ± 1000 mV
- Conductivity: 0...1000 mS/cm
- Dissolved oxygen: 0...20 mg/l, 0...200 %
- Temperature: 0...100°C
Cena na dotaz
0 Kč
Vč. DPH
0 Kč bez DPH
pH
- Multi-point (1...3) with up to three buffers out of eleven pre-porgrammed pH buffers .
- Reads pH with 0.01 pH resolution
mV
- Features mV calibration for accurate ORP measurements.
- Reads potentioals with 1 mV resolution.
Conductivity
- Use a 1 cm-1 electrode (standard) to measure from 0.1 µS/cm to 100 mS/cm.
- Use a 0.1 cm-1 electrode to measure from 0.01 µS/cm to 10 mS/cm.
- Use a 10 cm-1 electrode to measure from 1 µS/cm to 1000 mS/cm.
- Automatically selects correct range and frequency.
- Selectable reference temperature: 20° or 25°C
- One-point calibration with any of two preprogrammed standards
Dissolved oxygen
- Operates with a galvanic oxygen electrode requiring no polarisation time and no zero calibration.
- Reads dissolved oxygen with 0.01mg/l or 0.1% resolution
- Rapid air calibration
Temperature
- Reads temperature with 0.1°C resolution.
- Manuel or automatic temperature compensation.
- Calibrates temperature probe for quality measurements
Inputs
- One common input for pH and mV.
- One common input for conductivity and dissolved oxygen.
- One input for a Pt1000 automatic temperature probe.
- Low voltage DC input for a mains adapter.
Display
- Bright LCD screen for better readability.
- A white backlight automatically illuminates when operated on the mains.
- Stability indicator prompts the user when readings should be taken.
- The interactive LCD screen provides step by step instructionsin the language of your choice(English, Dutch, French, german).
- Shows a GLP report on the LCD screen.
Cabinet
- Robust dust and splash-proof cabinet.
Special features
- Three year warranty.
- Mains and rechargeable battery operation with programmable automatic switch-off.
- Optional 12V car adaptor.
Pre-programmed standards
- pH buffers: 1.68, 2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C)
- Conductivity: 1413 µS/cm, 12.88 mS/cm (at 25°C).
CODE | DESCRIPTION |
C5020 | Meter only (without electrodes) + 4NiMH batteries + mains adaptor |
C5020X | Meter kit without electrodes: C5010 + 2X50ml buffers (pH 4 and 7) + 50ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01 M KCL) + carrying case |
C5020P | Meter kit for pH: C5010 + pH/ATC electrode SP10T + 2x50 ml buffers (pH 4 and 7) + 50ml electrolyte (3M KCl) + carrying case |
C5020K | Meter kit for conductivity:C5010 + conductivity/ATC electrode SK10T + 50 ml conductivity standard (0.01 M KCL) + carrying case |
C5020Z | Meter kit for oxygen: C5010 + dissolved oxygen electrode SZ10T + carrying case |
C5020T | Meter kit complete: C5010 + pH/ATC electrode SP10T + conductivity/ATC electrode SK10T + dissolved oxygen electrode SZ10T + 2x50 ml buffers (pH 4 and 7) + 50ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01 M KCL) + carrying case |
A4049 | Car adaptor, 12V (optional) |