pH - mV - ion - conductivity - resistivity - salinity - TDS - dissolved oxygen - temperature
C3030
- pH: -2...+16 pH
- mV: ± 2000 mV
- Ion: 0.01 ng/l...100 g/l
- conductivity: 0...2000 mS/cm
- resistivity: 0...200 MΩ.cm
- salinity: 0.0...70.0
- TDS: 0...100 g/l
- dissolved oxygen:0...60mg/l, 0...600%
- air pressure: 600...+1300 hPa
- temperature: -5...+105°C
NEW ! Model C3430/C3431 are equipped with two extra DIN-8 connectors for 4-pole conductivity electrodes.
Cena na vyžiadanie
0,00 €
S DPH
0,00 € bez DPH
pH
- Multi-point (1...5) calibration for more linearity
- Selectable resolution frm 0.001 pH to 0.1 pH
- Automatic calibration with any of eleven pre-prorammed and five user specified pH buffers. Create your own buffer/temperature tables!
- Accepts pH electrodes with any zero point (Eo) between ±999 mV
mV
- Features mV calibration for accurate ORP measurements
- Selectable resolution from 0.1 mV to 1 mV
Ion
- Direct concentration measurement.
- Multi-point (2...5) calibration and an additional blank correction for measuring low concentrations.
Conductivity
- Multi-point (1...3) calibration for more linearity.
- An electrode with a typical cell constant of 1 cm-1 (standard) permits to measure from 0.01 µS/cm to 200 mS/cm in five ranges.
- An electrode with a typical cell constant of 0.1 cm-1 permits to measure from 0.001µS/cm to 20 mS/cm in five ranges.
- An electrode with a typical cell constant of 10 cm-1 permits to measure from 0.1µS/cm to 2000 mS/cm in five ranges.
- Automaticly selects correct range and frequency.
- Selectable reference temperature: 20°C or 25°C
- Automatic calibration with any of three preprogrammed and three user specified standard solutions.Create your own buffer/temperature tables!
- Allows to lock the initial conductivity range to avoid non-linear titration curves.
- Accurate low conductivity measurements by eliminating the capacitve component of the electrode and its cable (avoid the use of long cables!).
Dissolved oxygen
- Operates with a galvanic dissolved oxygen electrode requiring no polarisation time and no zero calibration.
- Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%)
- Automatic air pressure compensation 600-1300 hPa.
Temperature
- Reads temperatures with 0.1 °C resolution.
- Manuel or automatic temperature compensation (O2: 0...50°C).
- Calibrates temperature probe for quality measurements.
Inputs
- Two inputs for pH, mV, Ion, dissolved oxygen or conductivity + corresponding temperature and reference inputs.
- Low voltage DC input for e.g. a mains adaptor.
Outputs - two versions available:
- C3030: with USB communication port and RS232 interface.
- C3031: with Ethernet communication port and RS232 interface.
Data-logging
- Up to 12000 data sets can be stored manually or at a programmable interval.
- Allows to mix data from all ranges in the same table.
- Freely downloadable data acquisition software enables to view, store and edit the measurements in your computer.
Cabinet
- Robust dust and splash-proof cabinet.
- An optional wall mounting kit allows to fix the meter to any wall making more space available on the desk.
Display
- A large bright LCD screen with white backlight enables to view all channels individually or simultaneously.
- Stability indicator prompts the user when readings should be taken.
- Hold function allows to freeze the display for convenient reading or recording.
- The interactive LCD screen provides step by step instructions in the language of your choice (English, Dutch, French, German)
- Real-time clock displays time and date.
- Shows a GLP report on the LCD screen.
Special features
- Two-way communication with a computer using USB, Ethernet or RS232.
- Can be programmed to continue automatically with the measurements or data-logging after a power failure.
- Password protection prevents any unauthorised modificaton of the instruments' settngs.
- No electrical interference between pH/ORP/Ion and conductivity eletrodes in the same solution.
- Optional 12 V adaptor.
- Three year warranty.
GLP
- All procedures for a "Good Laboratory Practice" are on board.
Pre-programmed standards
- pH buffers: 1.68, 2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C)
- conductivity: 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C).
CODE | DESCRIPTION |
C3030 | Meter only (USB version) + USB cable + mains adaptor |
C3031 | Meter only (Ethernet version) + mains adaptor |
C3030X | Meter kit without electrodes: C3030 + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) + 3x50 ml conductivity standards (0.01, 0.1 and 1 M KCl) |
C3030P | Meter kit for pH: C3030 + pH/ATC electrode SP10T + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) |
C3030K | Meter kit for conductivity: C3030 + conductivity/ATC electrode SK10T + 3x50 ml conductivity standards (0.01, 0.1 and 1 M KCl) |
C3030Z | Meter kit for oxygen: C3030 + dissolved oxygen electrode SZ10T |
C3030T | Meter kit complete: C3030 + pH/ATC electrode SP10T + conductivity/ATC electrode SK10T + dissolved oxygen electrode SZ10T + 3x50 ml buffers (pH 4, 7 and 10) + 50 ml electrolyte (3M KCl) + 3x50 ml conductivity standards (0.01, 0.1 and 1 M KCl) |
SH300 | Flexible electrode holder (optional) |
A4800 | Wall mounting kit (optional) |
A4049 | Car adaptor, 12 V (optional) |