pH - mV - Ion - Conductivity - Resistivity - Salinity - TDS - Dissolved oxygen - Air pressure - Temperature
search
  • pH - mV - Ion - Conductivity - Resistivity - Salinity - TDS - Dissolved oxygen - Air pressure - Temperature

pH - mV - Ion - Conductivity - Resistivity - Salinity - TDS - Dissolved oxygen - Air pressure - Temperature

C6030

Specifications

  • pH: -2...+16 pH
  • mV: ±2000 mV
  • Ion:0.01 ng/l...100 g/l
  • Conductivity: 0...2000 mS/m
  • Resistivity: 0...200 MΩ.cm
  • Salinity: 0.0...70.0
  • TDS: 0...100 g/l
  • Dissolved oxygen: 0...60mg/l 0...600%
  • Air pressure: 600...1300hPa
  • Temperature: -5...+105°C

Cena na vyžiadanie

0,00 € S DPH

0,00 € bez DPH

pH

  • Mulit-point (1...5) calibration for more linearity.
  • Selectable reslution from 0.001 pH to 0.1 pH.
  • Automatic calibration with any of eleven pre-programmed and five user specified pH buffers.
    Create your own buffer/temperature tables!
  • Accepts mV electrodes with any zero point(Eo) between ±999mV.

mV

  • Features mV calibration for accurate ORP measurements
  • Selectable resolution from 0.1 mV to 1 mV

Ion

  • Direct concentration measurement.
  • Multi-point (2...5) calibration and an additional blank correction for measuring low concentrations.

Conductivity

  • Multi-point (1...3) calibration for more linearity.
  • An electrode with a typical cell constant of 1 cm-1(standard) permits to measure from 0.01 µS/cm to 200 mS/cm in five ranges.
  • An electrode with a typical cell constant of 0.1 cm-1  permits to measure from 0.001µS/cm to 20 mS/cm in five ranges.
  • An electrode with a typical cell constant of 10 cm-1 permits to measure from 0.1µS/cm to 2000 mS/cm in five ranges.
  • Automaticly selects correct range and frequency.
  • Selectable reference temperature: 20°C or 25°C     
  • Automatic calibration with any of three preprogrammed and three user specified standard solutions.
    Create your own buffer/temperature tables!
  • Allows to lock the initial conductivity range to avoid non-linear titration curves.
  • Accurate low conductivity measurements by eliminating the capacitve component of the electrode and its cable (avoid the use of long cables!).

Dissolved oxygen

  • Operates with a galvanic dissolved oxygen electrode requiring no polarisation time and no zero calibration.
  • Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%)
  • Manuel salinity compensation 0-40
  • Automatic air pressure compensation 600-1300 hPa.

Temperature

  • Reads temperatures with 0.1 °C resolution.
  • Manuel or automatic temperature compensation .
  • Calibrates temperature probe for quality measurements.

Inputs

  • One common input for all ranges + corresponding reference input
  • One input for a Pt1000 automatic temperature.
  • Low voltage DC input for e.g. a mains adaptor.

Outputs

  • Galvanically issolated USB communication port for connection to a computer.

Display

  • A large bright LCD screen for a better readability.
  • Stability indicator prompts the user when readings should be taken.
  • Hold function allows to freeze the display for convenient reading or recording.
  • The interactive LCD screen provides step by step instructions in the language of your choice (English, Dutch, French, German)
  • Real-time clock displays time and date.
  • Shows a GLP report on the LCD screen.

Data-logging

  • Up to 12000 data sets can be stored manually or at a programmable interval.
  • Allows to mix data  from all ranges in the same table.
  • Freely downloadable data acquisition software enables to view, store and edit the measurements in your computer.

Cabinet

  • Robust dust and splash-proof cabinet.

Special features

  • Calibration reminder 0...999 h.
  • Programmable recorder output
  • Two-way communication with a computer using USB
  • Programmable identification number for use with a printer or computer.
  • Password protection prevents any unauthorised modificaton of the instruments' settngs.
  • 2 way communication with a printer or computer using USB
  • Mains and rechargeable battery operation with programmable automatic switch-off.
  • Shows percentage of remaining battey capacity.
  • Optional 12 V adaptor.
  • Three year warranty.

GLP

  • All procedures for a "Good Laboratory Practice" are on board.

Pre-programmed standards

  • pH buffers: 1.68, 2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C)
  • conductivity: 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C).
CODE  DESCRIPTION
C6030 Meter only (without electrodes)+ USB cables +4 NiMH batteries + mains adaptor
C6030X Meter kit wihout electrodes: C6030 + 2X50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCL) + 50 ml conductivity standard (0.01 M KCL) + carrying case
C6030P Meter kit for pH: C6030 + pH/ATC electrode SP10T + 2X50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCL) + carrying case
C6030K Meter kit  for conductivity: C6030 + conductivity/ATC electrode SK10T + 50 ml conductivity standard (0.01 M KCL) + carrying case
C6030Z Meter for oxygen: C6030 + dissolved oxygen electrode SZ10T + carrying case
C6030T Meter kit for pH: C6030 + pH/ATC electrode SP10T + conductivity/ATC electrode SK10T + dissolved oxygen electrode SZ10T+ 2X50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCL)+ 50 ml conductivity standard (0.01 M KCL) + carrying case
SH300 Flexible electrode holder (optional)
A4049 Car adaptor, 12V (optional)